Frequently Asked Questions about This Product
1. How to reduce the wear of the intermediate ring?
If the fit clearance between the end face of the spacer ring and the end face of the main body is too large, it will lead to a reduction in the effective working surface of the claw and thus cause extrusion, exacerbating the wear of the coupling. Therefore, it is necessary to reduce the clearance.
For couplings with spacer rings made of aluminum bronze material, grease can be added in the fit clearance between them, and lubrication should be carried out on time to reduce wear.
2. What is the operating temperature range of the cross-ring coupling?
For spacer rings made of POM material, the operating temperature ranges from -20°C to +80°C. For spacer rings made of aluminum bronze material, the operating temperature ranges from -40°C to +150°C.
3. What are the characteristics of the cross-ring coupling?
This product has a high torque, is flexible in use, maintenance-free, and very simple to use and replace in the later stage.